Air conditioner running but not cooling: what to check

Check whether the air is cool, how strong the airflow is and which rooms are affected. That helps you describe the problem and choose the right service.

Wall-mounted air conditioner with cool airflow

The indoor unit makes its usual noise and blows air, but the room is still hot. The fan can run even if cooling hasn’t started. Tell the technician what you’re seeing: warm air with normal airflow, weak airflow, or cool air without a noticeable drop in room temperature.

Simple checks without tools

  1. Select COOL. This is usually marked with a snowflake. Set the temperature below the room temperature and allow the system to start as described in its manual. FAN alone does not cool the room, and DRY is primarily for dehumidifying.

  2. Make sure air can flow freely. Curtains and furniture shouldn’t block the unit or grilles. With the unit off, check the accessible user filter if the manual permits it. If airflow is still weak after the maintenance allowed by the manual, do not remove the cover. Arrange an inspection.

  3. Compare with how it used to work. If the air is cool but the room only gets hot during strong sunshine, close the windows and lower the blinds. Solar heat gain or the way air is distributed could be a factor. If the system used to cope in the same conditions, tell the technician.

  4. Compare rooms. On a typical multi-split, set all active indoor units to COOL. If a ducted system isn’t cooling just one room, check whether that zone is on and calling for cooling. If there’s a control issue, see our Airzone fault diagnosis service.

Why a refrigerant top-up shouldn’t be your first step

Poor cooling alone does not tell you that the system is short of refrigerant. Dirt and restricted airflow, a sensor fault, a control issue, a problem with the outdoor unit, or a leak could be responsible. A properly sealed refrigerant circuit doesn’t use up refrigerant like fuel. If the charge is genuinely low, the reason needs to be found and any leak addressed. See air conditioning leak detection and refrigerant charging for more information.

When to stop using the unit and call a technician

If you see ice, water leaking into the room or smoke, smell burning, or the circuit breaker trips, stop using the unit and leave it off until it has been checked. Don’t chip off ice, open the casing or touch the service valves. If the unit still blows warm air with normal airflow, or shuts down with an error, arrange a diagnostic visit.

Tell us the town, how many rooms aren’t cooling and which settings are shown on the controller. Send a photo of the error code or a short video, and a photo of the outdoor unit’s label if you can take it safely. A photo helps us identify the system. An on-site check confirms why it isn’t cooling properly.

Request an air conditioning diagnostic visit in Orihuela Costa, Torrevieja, Alicante or the surrounding areas.